Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.395
Filtrar
1.
J Cell Mol Med ; 28(9): e18316, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38722291

RESUMEN

Tissue engineering includes the construction of tissue-organ scaffold. The advantage of three-dimensional scaffolds over two-dimensional scaffolds is that they provide homeostasis for a longer time. The microbial community in Symbiotic culture of bacteria and yeast (SCOBY) can be a source for kombucha (kombu tea) production. In this study, it was aimed to investigate the usage of SCOBY, which produces bacterial cellulose, as a biomaterial and 3D scaffold material. 3D printable biomaterial was obtained by partial hydrolysis of oolong tea and black tea kombucha biofilms. In order to investigate the usage of 3D kombucha biomaterial as a tissue scaffold, "L929 cell line 3D cell culture" was created and cell viability was tested in the biomaterial. At the end of the 21st day, black tea showed 51% and oolong tea 73% viability. The cytotoxicity of the materials prepared by lyophilizing oolong and black tea kombucha beverages in fibroblast cell culture was determined. Black tea IC50 value: 7.53 mg, oolong tea IC50 value is found as 6.05 mg. Fibroblast viability in 3D biomaterial + lyophilized oolong and black tea kombucha beverages, which were created using the amounts determined to these values, were investigated by cell culture Fibroblasts in lyophilized and 3D biomaterial showed viability of 58% in black tea and 78% in oolong tea at the end of the 7th day. In SEM analysis, it was concluded that fibroblast cells created adhesion to the biomaterial. 3D biomaterial from kombucha mushroom culture can be used as tissue scaffold and biomaterial.


Asunto(s)
Materiales Biocompatibles , Supervivencia Celular , Impresión Tridimensional , Andamios del Tejido , Andamios del Tejido/química , Materiales Biocompatibles/farmacología , Materiales Biocompatibles/química , Animales , Ratones , Supervivencia Celular/efectos de los fármacos , Fibroblastos/efectos de los fármacos , Ingeniería de Tejidos/métodos , Línea Celular , Té de Kombucha
2.
PLoS One ; 19(5): e0301099, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38728291

RESUMEN

Beyond the smallest organisms, animals rely on tubes to transport cells, oxygen, nutrients, waste products, and a great variety of secretions. The cardiovascular system, lungs, gastrointestinal and genitourinary tracts, as well as major exocrine glands, are all composed of tubes. Paradoxically, despite their ubiquitous importance, most existing devices designed to study tubes are relatively complex to manufacture and/or utilize. The present work describes a simple method for generating tubes in vitro using nothing more than a low-cost 3D printer along with general lab supplies. The technology is termed "TruD", an acronym for true dimensional. Using this technology, it is readily feasible to cast tubes embedded in ECM with easy access to the lumen. The design is modular to permit more complex tube arrangements and to sustain flow. Importantly, by virtue of its simplicity, TruD technology enables typical molecular cell biology experiments where multiple conditions are assayed in replicate.


Asunto(s)
Impresión Tridimensional , Humanos , Animales , Impresión Tridimensional/instrumentación , Células Endoteliales/citología , Células Endoteliales/metabolismo
3.
Arch Dermatol Res ; 316(5): 147, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698273

RESUMEN

Mohs Micrographic Surgery (MMS) is effective for treating common cutaneous malignancies, but complex repairs may often present challenges for reconstruction. This paper explores the potential of three-dimensional (3D) bioprinting in MMS, offering superior outcomes compared to traditional methods. 3D printing technologies show promise in advancing skin regeneration and refining surgical techniques in dermatologic surgery. A PubMed search was conducted using the following keywords: "Three-dimensional bioprinting" OR "3-D printing" AND "Mohs" OR "Mohs surgery" OR "Surgery." Peer-reviewed English articles discussing medical applications of 3D bioprinting were included, while non-peer-reviewed and non-English articles were excluded. Patients using 3D MMS models had lower anxiety scores (3.00 to 1.7, p < 0.0001) and higher knowledge assessment scores (5.59 or 93.25% correct responses), indicating better understanding of their procedure. Surgical residents using 3D models demonstrated improved proficiency in flap reconstructions (p = 0.002) and knowledge assessment (p = 0.001). Additionally, 3D printing offers personalized patient care through tailored surgical guides and anatomical models, reducing intraoperative time while enhancing surgical. Concurrently, efforts in tissue engineering and regenerative medicine are being explored as potential alternatives to address organ donor shortages, eliminating autografting needs. However, challenges like limited training and technological constraints persist. Integrating optical coherence tomography with 3D bioprinting may expedite grafting, but challenges remain in pre-printing grafts for complex cases. Regulatory and ethical considerations are paramount for patient safety, and further research is needed to understand long-term effects and cost-effectiveness. While promising, significant advancements are necessary for full utilization in MMS.


Asunto(s)
Bioimpresión , Cirugía de Mohs , Impresión Tridimensional , Neoplasias Cutáneas , Humanos , Bioimpresión/métodos , Cirugía de Mohs/métodos , Neoplasias Cutáneas/cirugía , Ingeniería de Tejidos/métodos , Modelos Anatómicos , Procedimientos de Cirugía Plástica/métodos , Procedimientos de Cirugía Plástica/instrumentación , Colgajos Quirúrgicos , Piel , Medicina Regenerativa/métodos
4.
Artículo en Inglés | MEDLINE | ID: mdl-38722846

RESUMEN

INTRODUCTION: Three-dimensional (3D) printed models may help patients understand complex anatomic pathologies such as femoroacetabular impingement syndrome (FAIS). We aimed to assess patient understanding and satisfaction when using 3D printed models compared with standard imaging modalities for discussion of FAIS diagnosis and surgical plan. METHODS: A consecutive series of 76 new patients with FAIS (37 patients in the 3D model cohort and 39 in the control cohort) from a single surgeon's clinic were educated using imaging and representative 3D printed models of FAI or imaging without models (control). Patients received a voluntary post-visit questionnaire that evaluated their understanding of the diagnosis, surgical plan, and visit satisfaction. RESULTS: Patients in the 3D model cohort reported a significantly higher mean understanding of FAIS (90.0 ± 11.5 versus 79.8 ± 14.9 out of 100; P = 0.001) and surgery (89.5 ± 11.6 versus 81.0 ± 14.5; P = 0.01) compared with the control cohort. Both groups reported high levels of satisfaction with the visit. CONCLUSION: In this study, the use of 3D printed models in clinic visits with patients with FAIS improved patients' perceived understanding of diagnosis and surgical treatment.


Asunto(s)
Pinzamiento Femoroacetabular , Modelos Anatómicos , Satisfacción del Paciente , Impresión Tridimensional , Humanos , Pinzamiento Femoroacetabular/cirugía , Pinzamiento Femoroacetabular/diagnóstico por imagen , Femenino , Masculino , Adulto , Persona de Mediana Edad , Educación del Paciente como Asunto , Encuestas y Cuestionarios , Comprensión
5.
J Orthop Surg Res ; 19(1): 273, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698477

RESUMEN

BACKGROUND: Talar malignant tumor is extremely rare. Currently, there are several alternative management options for talus malignant tumor including below-knee amputation, tibio-calcaneal arthrodesis, and homogenous bone transplant while their shortcomings limited the clinical application. Three-dimensional (3D) printed total talus prosthesis in talus lesion was reported as a useful method to reconstruct talus, however, most researches are case reports and its clinical effect remains unclear. Therefore, the current study was to explore the application of 3D printed custom-made modular prosthesis in talus malignant tumor. METHODS: We retrospectively analyzed the patients who received the 3D printed custom-made modular prosthesis treatment due to talus malignant tumor in our hospital from February 2016 to December 2021. The patient's clinical data such as oncology outcome, operation time, and volume of blood loss were recorded. The limb function was evaluated with the Musculoskeletal Tumor Society 93 (MSTS-93) score, The American Orthopedic Foot and Ankle Society (AOFAS) score; the ankle joint ranges of motion as well as the leg length discrepancy were evaluated. Plain radiography and Tomosynthesis-Shimadzu Metal Artefact Reduction Technology (T-SMART) were used to evaluate the position of prosthesis and the osseointegration. Postoperative complications were recorded. RESULTS: The average patients' age and the follow-up period were respectively 31.5 ± 13.1 years; and 54.8 months (range 26-72). The medium operation time was 2.4 ± 0.5 h; the intraoperative blood loss was 131.7 ± 121.4 ml. The mean MSTS-93 and AOFAS score was 26.8 and 88.5 respectively. The average plantar flexion, dorsiflexion, varus, and valgus were 32.5, 9.2, 10.8, and 5.8 degree respectively. One patient had delayed postoperative wound healing. There was no leg length discrepancy observed in any patient and good osseointegration was observed on the interface between the bone and talus prosthesis in all subjects. CONCLUSION: The modular structure of the prosthesis developed in this study seems to be convenient for prosthesis implantation and screws distribution. And the combination of solid and porous structure improves the initial stability and promotes bone integration. Therefore, 3D printed custom-made modular talus prosthesis could be an alternative option for talus reconstruction in talus malignant tumor patients.


Asunto(s)
Neoplasias Óseas , Impresión Tridimensional , Diseño de Prótesis , Astrágalo , Humanos , Astrágalo/cirugía , Astrágalo/diagnóstico por imagen , Masculino , Adulto , Femenino , Neoplasias Óseas/cirugía , Neoplasias Óseas/diagnóstico por imagen , Estudios Retrospectivos , Persona de Mediana Edad , Adulto Joven , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Adolescente , Articulación del Tobillo/cirugía , Articulación del Tobillo/diagnóstico por imagen , Oseointegración , Resultado del Tratamiento , Rango del Movimiento Articular , Prótesis e Implantes
6.
BMC Surg ; 24(1): 148, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734630

RESUMEN

BACKGROUND & AIMS: Complications after laparoscopic liver resection (LLR) are important factors affecting the prognosis of patients, especially for complex hepatobiliary diseases. The present study aimed to evaluate the value of a three-dimensional (3D) printed dry-laboratory model in the precise planning of LLR for complex hepatobiliary diseases. METHODS: Patients with complex hepatobiliary diseases who underwent LLR were preoperatively enrolled, and divided into two groups according to whether using a 3D-printed dry-laboratory model (3D vs. control group). Clinical variables were assessed and complications were graded by the Clavien-Dindo classification. The Comprehensive Complication Index (CCI) scores were calculated and compared for each patient. Multivariable analysis was performed to determine the risk factors of postoperative complications. RESULTS: Sixty-two patients with complex hepatobiliary diseases underwent the precise planning of LLR. Among them, thirty-one patients acquired the guidance of a 3D-printed dry-laboratory model, and others were only guided by traditional enhanced CT or MRI. The results showed no significant differences between the two groups in baseline characters. However, compared to the control group, the 3D group had a lower incidence of intraoperative blood loss, as well as postoperative 30-day and major complications, especially bile leakage (all P < 0.05). The median score on the CCI was 20.9 (range 8.7-51.8) in the control group and 8.7 (range 8.7-43.4) in the 3D group (mean difference, -12.2, P = 0.004). Multivariable analysis showed the 3D model was an independent protective factor in decreasing postoperative complications. Subgroup analysis also showed that a 3D model could decrease postoperative complications, especially for bile leakage in patients with intrahepatic cholelithiasis. CONCLUSION: The 3D-printed models can help reduce postoperative complications. The 3D-printed models should be recommended for patients with complex hepatobiliary diseases undergoing precise planning LLR.


Asunto(s)
Laparoscopía , Hepatopatías , Complicaciones Posoperatorias , Impresión Tridimensional , Humanos , Femenino , Masculino , Persona de Mediana Edad , Laparoscopía/métodos , Laparoscopía/efectos adversos , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Hepatopatías/cirugía , Anciano , Enfermedades de las Vías Biliares/prevención & control , Enfermedades de las Vías Biliares/cirugía , Enfermedades de las Vías Biliares/etiología , Hepatectomía/métodos , Hepatectomía/efectos adversos , Adulto , Estudios Retrospectivos , Estudios de Cohortes
7.
J Plast Surg Hand Surg ; 59: 46-52, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747532

RESUMEN

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Fracturas Mal Unidas , Osteotomía , Fracturas del Radio , Humanos , Femenino , Osteotomía/métodos , Osteotomía/instrumentación , Persona de Mediana Edad , Fracturas del Radio/cirugía , Fracturas del Radio/diagnóstico por imagen , Anciano , Fracturas Mal Unidas/cirugía , Fracturas Mal Unidas/diagnóstico por imagen , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Impresión Tridimensional , Cirugía Asistida por Computador , Imagenología Tridimensional , Tornillos Óseos , Tomografía Computarizada por Rayos X
8.
Clin Oral Investig ; 28(6): 312, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748326

RESUMEN

OBJECTIVES: Material chemistry and workflow variables associated with the fabrication of dental devices may affect the biocompatibility of the dental devices. The purpose of this study was to compare digital and conventional workflow procedures in the manufacturing of acrylic-based occlusal devices by assessing the cytotoxic potential of leakage products. METHODS: Specimens were manufactured by 3D printing (stereolithography and digital light processing), milling, and autopolymerization. Print specimens were also subjected to different post-curing methods. To assess biocompatibility, a human tongue epithelial cell line was exposed to material-based extracts. Cell viability was measured by MTT assay while Western blot assessed the expression level of selected cytoprotective proteins. RESULTS: Extracts from the Splint 2.0 material printed with DLP technology and post-cured with the Asiga Flash showed the clearest loss of cell viability. The milled and autopolymerized materials also showed a significant reduction in cell viability. However, by storing the autopolymerized material in dH2O for 12 h, no significant viability loss was observed. Increased levels of cytoprotective proteins were seen in cells exposed to extracts from the print materials and the autopolymerized material. Similarly to the effect on viability loss, storing the autopolymerized material in dH2O for 12 h reduced this effect. CONCLUSIONS/CLINICAL RELEVANCE: Based on the biocompatibility assessments, clinical outcomes of acrylic-based occlusal device materials may be affected by the choice of manufacturing technique and workflow procedures.


Asunto(s)
Materiales Biocompatibles , Supervivencia Celular , Ensayo de Materiales , Impresión Tridimensional , Humanos , Materiales Biocompatibles/química , Técnicas In Vitro , Resinas Acrílicas/química , Línea Celular , Western Blotting
9.
J Rehabil Med ; 56: jrm39946, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38742877

RESUMEN

OBJECTIVE: To assess the preliminary effectiveness of three-dimensional printed orthoses compared with conventionally custom-fabricated orthoses in persons with chronic hand conditions on performance of daily activities, hand function, quality of life, satisfaction, and production time and costs. DESIGN: Interventional feasibility study. SUBJECTS: Chronic hand orthotic users (n = 21). METHODS: Participants received a new three-dimensional printed orthosis according to the same type as their current orthosis, which served as the control condition. Primary outcome was performance of daily activities (Patient-Reported Outcomes Measurement Information System-Upper Extremity; Michigan Hand Questionnaire). Secondary outcomes were hand function, quality of life, and satisfaction. Furthermore, production time and costs were recorded. RESULTS: At 4 months' follow-up, no significant differences were found between three-dimensional printed orthoses and participants' existing conventional orthoses on activity performance, hand function, and quality of life. Satisfaction with the three-dimensional printed orthosis was significantly higher and the production time and costs for three-dimensional printed orthoses were significantly lower compared with conventional orthoses. The three-dimensional printed orthosis was preferred by 79% of the participants. CONCLUSIONS: This feasibility study in chronic hand conditions suggests that three-dimensional printed orthoses are similar to conventional orthoses in terms of activity performance, hand function, and quality of life. Satisfaction, and production time and costs favoured the three-dimensional printed hand orthoses.


Asunto(s)
Actividades Cotidianas , Estudios de Factibilidad , Aparatos Ortopédicos , Impresión Tridimensional , Calidad de Vida , Humanos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Enfermedad Crónica , Satisfacción del Paciente , Mano , Anciano
10.
PLoS One ; 19(5): e0303218, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38743741

RESUMEN

This study examines the effects of the rising live streaming e-commerce on the 3DP supply chain, employing system dynamics to develop separate models for pure polymer and polymer-metal mixed printing. The analysis focuses on optimizing the 3DP supply chain configuration. Results indicate that, based solely on printing time, cost, and quality metrics, Corporate-live-3DP services are optimal for live commerce scenarios. However, despite this, Private-live-3DP maintains a substantial consumer base in practice, as evidenced by literature data and case studies. Both models pose significant challenges to conventional supply chains, necessitating adaptation. For Corporate-live-3DP, optimization strategies may include technology advancements, digital transformation, agile manufacturing, global network optimization, innovative management, collaborative R&D, fine-tuned inventory control, quality system upgrades, talent development, and organizational restructuring. Conversely, Private-live-3DP can be optimized through consolidation of private 3D printing resources, demand prediction and order optimization, supply chain collaboration platforms, quality management extensions, inventory strategy adjustments, increased transparency, regulatory compliance, and risk mitigation measures.


Asunto(s)
Impresión Tridimensional , Comercio , Polímeros/química , Humanos
11.
Sci Rep ; 14(1): 11003, 2024 05 14.
Artículo en Inglés | MEDLINE | ID: mdl-38744985

RESUMEN

The future of organ and tissue biofabrication strongly relies on 3D bioprinting technologies. However, maintaining sterility remains a critical issue regardless of the technology used. This challenge becomes even more pronounced when the volume of bioprinted objects approaches organ dimensions. Here, we introduce a novel device called the Flexible Unique Generator Unit (FUGU), which is a unique combination of flexible silicone membranes and solid components made of stainless steel. Alternatively, the solid components can also be made of 3D printed medical-grade polycarbonate. The FUGU is designed to support micro-extrusion needle insertion and removal, internal volume adjustment, and fluid management. The FUGU was assessed in various environments, ranging from custom-built basic cartesian to sophisticated 6-axis robotic arm bioprinters, demonstrating its compatibility, flexibility, and universality across different bioprinting platforms. Sterility assays conducted under various infection scenarios highlight the FUGU's ability to physically protect the internal volume against contaminations, thereby ensuring the integrity of the bioprinted constructs. The FUGU also enabled bioprinting and cultivation of a 14.5 cm3 human colorectal cancer tissue model within a completely confined and sterile environment, while allowing for the exchange of gases with the external environment. This FUGU system represents a significant advancement in 3D bioprinting and biofabrication, paving the path toward the sterile production of implantable tissues and organs.


Asunto(s)
Bioimpresión , Reactores Biológicos , Impresión Tridimensional , Bioimpresión/métodos , Humanos , Ingeniería de Tejidos/métodos , Esterilización , Andamios del Tejido
12.
BMC Oral Health ; 24(1): 560, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745168

RESUMEN

BACKGROUND: Solitary Bone Cyst (SBC), also known as a simple bone cyst, hemorrhagic cyst, or traumatic cyst is classified by the WHO among non-odontogenic benign lesions of the jaw. The article explores the use of a static 3D-printed surgical guide to treat mandibular SBC, emphasizing a minimally surgical approach for this lesion. CASE PRESENTATION: A 20-year-old woman was referred for a persistent mandibular SBC lacuna, without specific complaints. Her medical history included a previous bone trepanation for a SBC in the same area, radiologically and surgically confirmed. X-ray assessment showed a well-defined unilocular radiolucency surrounding the root of the first left lower molar (tooth #36), measuring 10 × 10 mm. Pulp sensitivity was normal. CBCT data and STL files of dental cast were obtained preoperatively and registered. A 3D-printed surgical guide was used for minimally invasive trepanation of the buccal cortical. The simulation used a targeted endodontic microsurgery approach in order to determine axis and diameter of the trephine. Surgery was performed under local anesthesia. The guide was tooth supported integrating tubes and a fork for guiding precise trepanation. A 3.5 mm round bone window was created, leaving an empty cavity confirming SBC diagnosis and permitting bone curettage. A blood clot was obtained to promote bone healing. Complete reossification was observed after 6 months. The follow-up at 2 years confirmed a complete bone healing with normal pulp sensitivity. DISCUSSION: The 3D-printed windowed surgical guide with dental support offers big advantages, including improved visibility and reduced errors. Compared to traditional guides, it eliminates visual hindrance and allows easier and quick access to confined areas as well as an improved irrigation during drilling process. The article also highlights the importance of preoperative planning while acknowledging potential limitations and errors and surgical complications. CONCLUSION: The use of the 3D-printed surgical guide could be used in routine for minimally invasive intervention of SBC. This case also demonstrates the potential utility of this approach in various procedures in oral and maxillofacial surgery. The technique provides precise localization, reducing complications and enhances operative efficiency.


Asunto(s)
Procedimientos Quirúrgicos Mínimamente Invasivos , Impresión Tridimensional , Humanos , Femenino , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Adulto Joven , Tomografía Computarizada de Haz Cónico , Enfermedades Mandibulares/cirugía , Enfermedades Mandibulares/diagnóstico por imagen , Quistes Maxilomandibulares/cirugía , Quistes Maxilomandibulares/diagnóstico por imagen
13.
Biomed Phys Eng Express ; 10(4)2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38697045

RESUMEN

Whole-body counters (WBC) are used in internal dosimetry forin vivomonitoring in radiation protection. The calibration processes of a WBC set-up include the measurement of a physical phantom filled with a certificate radioactive source that usually is referred to a standard set of individuals determined by the International Commission on Radiological Protection (ICRP). The aim of this study was to develop an anthropomorphic and anthropometric female physical phantom for the calibration of the WBC systems. The reference female computational phantom of the ICRP, now called RFPID (Reference Female Phantom for Internal Dosimetry) was printed using PLA filament and with an empty interior. The goal is to use the RFPID to reduce the uncertainties associated within vivomonitoring system. The images which generated the phantom were manipulated using ImageJ®, Amide®, GIMP®and the 3D Slicer®software. RFPID was split into several parts and printed using a 3D printer in order to print the whole-body phantom. The newly printed physical phantom RFPID was successfully fabricated, and it is suitable to mimic human tissue, anatomically similar to a human body i.e., size, shape, material composition, and density.


Asunto(s)
Fantasmas de Imagen , Impresión Tridimensional , Recuento Corporal Total , Humanos , Femenino , Recuento Corporal Total/métodos , Calibración , Protección Radiológica/métodos , Protección Radiológica/instrumentación , Radiometría/métodos , Radiometría/instrumentación , Antropometría
14.
Biofabrication ; 16(3)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38697099

RESUMEN

Rotator cuff tear is one of the most common musculoskeletal disorders, which often results in recurrent shoulder pain and limited movement. Enthesis is a structurally complex and functionally critical interface connecting tendon and bone that plays an essential role in maintaining integrity of the shoulder joint. Despite the availability of advanced surgical procedures for rotator cuff repair, there is a high rate of failure following surgery due to suboptimal enthesis healing and regeneration. Novel strategies based on tissue engineering are gaining popularity in improving tendon-bone interface (TBI) regeneration. Through incorporating physical and biochemical cues into scaffold design which mimics the structure and composition of native enthesis is advantageous to guide specific differentiation of seeding cells and facilitate the formation of functional tissues. In this review, we summarize the current state of research in enthesis tissue engineering highlighting the development and application of biomimetic scaffolds that replicate the gradient TBI. We also discuss the latest techniques for fabricating potential translatable scaffolds such as 3D bioprinting and microfluidic device. While preclinical studies have demonstrated encouraging results of biomimetic gradient scaffolds, the translation of these findings into clinical applications necessitates a comprehensive understanding of their safety and long-term efficacy.


Asunto(s)
Manguito de los Rotadores , Ingeniería de Tejidos , Andamios del Tejido , Humanos , Andamios del Tejido/química , Manguito de los Rotadores/cirugía , Animales , Materiales Biomiméticos/química , Regeneración , Biomimética , Lesiones del Manguito de los Rotadores/cirugía , Impresión Tridimensional
15.
Biomed Mater ; 19(4)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38697199

RESUMEN

Porous tantalum scaffolds offer a high degree of biocompatibility and have a low friction coefficient. In addition, their biomimetic porous structure and mechanical properties, which closely resemble human bone tissue, make them a popular area of research in the field of bone defect repair. With the rapid advancement of additive manufacturing, 3D-printed porous tantalum scaffolds have increasingly emerged in recent years, offering exceptional design flexibility, as well as facilitating the fabrication of intricate geometries and complex pore structures that similar to human anatomy. This review provides a comprehensive description of the techniques, procedures, and specific parameters involved in the 3D printing of porous tantalum scaffolds. Concurrently, the review provides a summary of the mechanical properties, osteogenesis and antibacterial properties of porous tantalum scaffolds. The use of surface modification techniques and the drug carriers can enhance the characteristics of porous tantalum scaffolds. Accordingly, the review discusses the application of these porous tantalum materials in clinical settings. Multiple studies have demonstrated that 3D-printed porous tantalum scaffolds exhibit exceptional corrosion resistance, biocompatibility, and osteogenic properties. As a result, they are considered highly suitable biomaterials for repairing bone defects. Despite the rapid development of 3D-printed porous tantalum scaffolds, they still encounter challenges and issues when used as bone defect implants in clinical applications. Ultimately, a concise overview of the primary challenges faced by 3D-printed porous tantalum scaffolds is offered, and corresponding insights to promote further exploration and advancement in this domain are presented.


Asunto(s)
Materiales Biocompatibles , Sustitutos de Huesos , Huesos , Osteogénesis , Impresión Tridimensional , Tantalio , Ingeniería de Tejidos , Andamios del Tejido , Tantalio/química , Andamios del Tejido/química , Porosidad , Humanos , Materiales Biocompatibles/química , Ingeniería de Tejidos/métodos , Animales , Sustitutos de Huesos/química , Ensayo de Materiales , Regeneración Ósea
16.
BMC Oral Health ; 24(1): 554, 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38735924

RESUMEN

This in vitro study compared various obturation techniques with bioceramic sealers for filling C-shaped 3D-printed replicas. A mandibular molar with a C-shaped root canal with a C1 configuration was obtained. After instrumenting with M3 Pro Gold files (United Dental, Shanghai, China) up to size #30/0.04, a CBCT scan of the tooth was taken. Sixty 3D-printed replicas of the tooth were created. The samples were obturated with EndoSeal TCS sealer (E. TCS; Maruchi, Wonju, Korea) or EndoSeal MTA (E. MTA; Maruchi, Wonju, Korea) (n = 30). The samples in each group were obturated with the following techniques (n = 10): (1) single-cone technique (SC), (2) SC with ultrasonic activation (UA), and (3) cold hydraulic compaction (CHC). Following incubation, the replicas' apical, middle, and coronal thirds were inspected under a digital microscope, and the proportion of filling material and void were calculated. Also, the obturation time and sealer extrusion were recorded. Data were analyzed using ANOVA, LSD post-hoc, and the chi-square tests (α = 0.05). The results indicated that in the apical third, E. TCS-SC, E. TCS-UA, and E. MTA-UA had the lowest void percentage among groups (p < 0.05). In the middle thirds, samples obturated with E. TCS-UA showed a significantly lower void percentage among all groups (p < 0.05). However, in the coronal third, E. TCS-CHC showed the least void percentage (p < 0.05), followed by E. TCS-UA and E. MTA-CHC. The E. TCS-SC and E. TCS-UA were the least time-consuming methods (p < 0.05). Sealer extrusion significantly differed among the groups, with E. MTA-UA and E. TCS-UA showing higher incidence (p = 0.019). It was concluded that E. TCS-UA was the most convenient obturation technique. However, care must be taken when obturating the canals with high flow and ultrasonic activation near the vital anatomical landmarks.


Asunto(s)
Impresión Tridimensional , Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Obturación del Conducto Radicular/métodos , Humanos , Combinación de Medicamentos , Diente Molar/diagnóstico por imagen , Técnicas In Vitro , Compuestos de Calcio , Óxidos , Cavidad Pulpar/diagnóstico por imagen , Compuestos de Aluminio , Tomografía Computarizada de Haz Cónico/métodos , Silicatos
17.
BMC Oral Health ; 24(1): 555, 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38735948

RESUMEN

OBJECTIVE: This study aimed to evaluate the effect of fence tray matching care (FTMC) in bracket bonding by measuring excess adhesive, as well as linear and angular deviations, and by comparing it with the half-wrapped tray (HWT). MATERIALS AND METHODS: An intraoral scanner was used to acquire data on the maxillary dental arch of a patient with periodontitis.Furthermore, 20 maxillary dental arch models were 3D printed. Using 3Shape, PlastyCAD software, and 3D printing technology, 10 FTMC (method I) and HWT (method II) were obtained. By preoperative preparation, intraoperative coordination, and postoperative measurement, the brackets were transferred from the trays to the 3D-printed maxillary dental arch models. Additionally, the bracket's excess adhesive as well as linear and angular deviations were measured, and the differences between the two methods were analyzed. RESULTS: Excess adhesive was observed in both methods, with FTMC showing less adhesive (P< 0.001), with a statistical difference. Furthermore, HWT's vertical, tip and torque, which was significantly greater than FTMC (P< 0.05), with no statistical difference among other respects. The study data of incisors, canines, and premolars, showed that the premolars had more adhesive residue and were more likely to have linear and angular deviations. CONCLUSIONS: The FTMC had higher bracket bonding effect in comparison to HWT, and the adhesive residue, linear and angular deviations are smaller. The fence tray offers an intuitive view of the precise bonding of the bracket, and can remove excess adhesive to prevent white spot lesions via care, providing a different bonding method for clinical applications.


Asunto(s)
Recubrimiento Dental Adhesivo , Soportes Ortodóncicos , Humanos , Recubrimiento Dental Adhesivo/métodos , Técnicas In Vitro , Modelos Dentales , Adhesivos , Impresión Tridimensional , Cementos Dentales , Arco Dental
18.
Mikrochim Acta ; 191(6): 310, 2024 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-38714566

RESUMEN

A ratiometric fluorescence sensor has been established based on dual-excitation carbon dots (D-CDs) for the detection of flavonoids (morin is chosen as the typical detecting model for flavonoids). D-CDs were prepared using microwave radiation with o-phenylenediamine and melamine and exhibit controllable dual-excitation behavior through the regulation of their concentration. Remarkably, the short-wavelength excitation of D-CDs can be quenched by morin owing to the inner filter effect, while the long-wavelength excitation remains insensitive, serving as the reference signal. This contributes to the successful design of an excitation-based ratiometric sensor. Based on the distinct and differentiated variation of excitation intensity, morin can be determined from 0.156 to 110 µM with a low detection limit of 0.156 µM. In addition, an intelligent and visually lateral flow sensing device is developed for the determination  of morin content in real samples with satisfying recoveries, which indicates the potential application for human health monitoring.


Asunto(s)
Carbono , Flavonoides , Límite de Detección , Nitrógeno , Impresión Tridimensional , Puntos Cuánticos , Espectrometría de Fluorescencia , Flavonoides/análisis , Flavonoides/química , Carbono/química , Puntos Cuánticos/química , Espectrometría de Fluorescencia/métodos , Nitrógeno/química , Colorantes Fluorescentes/química , Humanos , Flavonas
19.
BMC Oral Health ; 24(1): 538, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38715004

RESUMEN

BACKGROUND: The introduction of auxiliaries such as composite attachment has improved the force delivery of clear aligner (CA) therapy. However, the placement of the attachment may give rise to a flash, defined as excess resin around the attachment which may affect CA force delivery. This in vitro study aims to determine the differences in the force generated by the attachment in the presence or absence of flash in CA. MATERIALS AND METHODS: Tristar Trubalance aligner sheets were used to fabricate the CAs. Thirty-four resin models were 3D printed and 17 each, were bonded with ellipsoidal or rectangular attachments on maxillary right central incisors. Fuji Prescale pressure film was used to measure the force generated by the attachment of CA. The images of colour density produced on the films were processed using a calibrated pressure mapping system utilising image processing techniques and topographical force mapping to quantify the force. The force measurement process was repeated after the flash was removed from the attachment using tungsten-carbide bur on a slow-speed handpiece. RESULTS: The intraclass correlation coefficient showed excellent reliability (ICC = 0.96, 95% CI = 0.92-0.98). The average mean force exerted by ellipsoidal attachments with flash was 8.05 ± 0.16 N, while 8.11 ± 0.18 N was without flash. As for rectangular attachments, the average mean force with flash was 8.48 ± 0.27 N, while 8.53 ± 0.13 N was without flash. Paired t-test revealed no statistically significant difference in the mean force exerted by CA in the presence or absence of flash for both ellipsoidal (p = 0.07) and rectangular attachments (p = 0.41). Rectangular attachments generated statistically significantly (p < 0.001) higher mean force than ellipsoidal attachments for flash and without flash. CONCLUSION: Although rectangular attachment generated a significantly higher force than ellipsoidal attachment, the force generated by both attachments in the presence or absence of flash is similar (p > 0.05).


Asunto(s)
Técnicas de Movimiento Dental , Humanos , Técnicas In Vitro , Técnicas de Movimiento Dental/instrumentación , Análisis del Estrés Dental , Diseño de Aparato Ortodóncico , Resinas Compuestas/química , Impresión Tridimensional
20.
Int J Esthet Dent ; 19(2): 186-194, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726859

RESUMEN

OBJECTIVE: A diagnostic mock-up is a key tool that allows a preview of the outcome of an esthetic restoration. With recent developments in CAD/CAM technology, it is important to understand the pros and cons of chairside digital dentistry and the restorative materials used. The aim of the present case report is to describe in detail the use of a 3D-printed mock-up fabricated from a polymer-based material for an esthetic treatment plan within a fully digital workflow. CASE REPORT: A 45-year-old female patient presented at the clinic concerned about her esthetic appearance and the color of her anterior incisors. After a conclusive diagnosis, a restoration was planned using ceramic veneers from maxillary premolar to premolar. For a preview visualization of the outcome, an intraoral scanner was used to obtain 3D images and to allow the design of a digital smile. The template STL file was exported to a 3D printer and a 0.6-mm mock-up in A3-shade 3D resin was produced after 25 min. The mock-up was tested through a try-in and approved by the patient. As a result, the printed mock-up was considered predictable and reliable for the final restoration. CONCLUSIONS: The ease, speed, and reduced costs derived from the digital workflow, in conjunction with the accuracy of the mock-up, made the procedure highly efficient and recommendable.


Asunto(s)
Diseño Asistido por Computadora , Estética Dental , Impresión Tridimensional , Humanos , Femenino , Persona de Mediana Edad , Coronas con Frente Estético , Diseño de Prótesis Dental/métodos , Cerámica , Incisivo/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA